Tite-Loc
Tite-Loc Panels combine structural panel performance with architectural
panel aesthetics. TITE-LOC Panels are corrective leveled to provide superior
panel flatness. A factory-applied sealant bead is applied for additional
weather resistance. Maximum panel length is 64 feet and minimum panel
length is 4 feet. Consult factory for longer lengths. Tite-Loc
Panels feature a 2” leg height that requires mechanical field
seaming after installation. Panels have a concealed-fastener floating
clip system designed to allow for thermal expansion/contraction. For
further details, please contact PAC.
Trim
All flashing and trim will be fabricated by manufacturer or qualified
fabricator. Flashing shall be PAC-CLAD aluminum (.032-.063 gauge as
specified) or PAC-CLAD steel (24 ga. or 22 ga. as specified). A 20 year,
non-prorated finish warranty can be supplied covering finish performance.
Installation
Tite-Loc Panels are intended for use in architectural and structural
roofing. Substrates may include 5/8” (min.) plywood, nailboard
insulation or equal with an underlayment of ice and water shield or
30# (min.) roofing felt applied horizontally from eave to ridge. Other
substrates may include metal decking, purlins or rigid insulation in
conjunction with bearing plates.
A minimum 1/2:12 pitch is required. Contact Petersen for
further detail assistance on projects. For Coastal applications, aluminum
panels along with stainless steel clips must be used for warranty. Consult
a local architect/engineer for compliance with local codes and conditions.
Tite-Loc Panels
Tite-Loc Panels are factory-formed to length and field seamed to a 90?
lock. Tite-Loc panels have been designed for application on roof slopes
as low as 1/2:12 pitch. Tite-Loc panels are available in 12”,
16” and 18” widths. Materials available include 22 and 24
gauge steel; .032 and .040 aluminum.
Tite Loc Seaming
The Tite-Loc seamer is bi-directional, offering labor savings with the
ability to travel up and down slope. However, the seamer should only
be used up slope on roofs with a pitch of 4:12 or less.
Curved Tite-Loc Panels
Tite-Loc Panels can be curved to a minimum radius
of 20’-0”. Tite-Loc curving can be done in the field or
at the factory depending on the radius and length of the panel. For
more details about our capabilities, please contact Petersen Aluminum
Corporation.
Contact
Conklin today for a FREE estimate regarding our exclusive
line of Pac Clad, Pac-Clad
Colors, Snap-Clad, Tite-Loc,
Tite-Loc Plus, Tite-Loc
HS, Snap-On Standing Seam,
High Snap-On Standing Seam,
Snap-On Batten, Redi-Roof
Standing Seam, Integral
Standing Seam, Integral Batten,
Edge-Loc, 7.2
Panel, 1/2" &
7/8" Corrugated, R-41 &
R-36 Panels, Snow Guards and Pac
Solar Series
|