Tite-Loc-Plus
Tite-Loc Plus Panels combine structural panel performance with architectural
panel aesthetics. Tite-Loc Plus Panels are corrective leveled to provide
superior panel flatness. A factory-applied sealant bead is applied for
additional weather resistance. Maximum panel length is 64 feet and minimum
panel length is 4 feet. Consult factory for longer lengths. Tite-Loc
Plus Panels feature a 2” leg height that requires mechanical field
seaming to 180 degrees after installation. Panels have a concealed-fastener
floating clip system designed to allow for thermal expansion/contraction.
For further details, please contact PAC.
Trim
All flashing and trim will be fabricated by manufacturer or qualified
fabricator. Flashing shall be PAC-CLAD aluminum (.032-.063 gauge as
specified) or PAC-CLAD steel (24 ga. or 22 ga. as specified). A 20 year,
non-prorated finish warranty can be supplied covering finish performance.
Installation
Tite-Loc Plus Panels are intended for use in architectural and structural
roofing. Substrates may include 5/8” (min.) plywood, nailboard
insulation or equal with an underlayment of ice and water shield or
30# (min.) roofing felt applied horizontally from eave to ridge. Other
substrates may include metal decking, purlins or rigid insulation in
conjunction with bearing plates.
A minimum 1/2:12 pitch is required. Contact Petersen for
further detail assistance on projects. For Coastal applications, aluminum
panels along with stainless steel clips must be used for warranty. Consult
a local architect/engineer for compliance with local codes and conditions.
Tite-Loc Plus Panels
Tite-Loc Plus Panels are factory-formed to length and designed to be
field-seamed to 180?. The panel combines an attractive thin-rib profile
with superior structural performance. Tite-Loc Plus panels are designed
for application over a wide variety of substrates in slopes as low as
1/2:12 pitch. Tite-Loc Plus panels are available in 12”, 16”
and 18” widths. Materials available include 22 and 24 gauge steel;
.032 and .040 aluminum.
Tite-Loc Plus Seaming
The Tite Loc Plus seamer can only run in one direction.
The Tite Loc Plus panels should be installed from left to right to ensure
the seamer travels down slope. The seamer will not travel up slope on
a roof pitch greater than 4:12.
Contact
Conklin today for a FREE estimate regarding our exclusive
line of Pac Clad, Pac-Clad
Colors, Snap-Clad, Tite-Loc,
Tite-Loc Plus, Tite-Loc
HS, Snap-On Standing Seam,
High Snap-On Standing Seam,
Snap-On Batten, Redi-Roof
Standing Seam, Integral
Standing Seam, Integral Batten,
Edge-Loc, 7.2
Panel, 1/2" &
7/8" Corrugated, R-41 &
R-36 Panels, Snow Guards and Pac
Solar Series
|